Δημοσίευση

Assessment of absolute Tc-99m tetrofosmin retention in the myocardium as an index of myocardial blood flow and coronary flow reserve by gated-SPECT/CT: a feasibility study.

ΤίτλοςAssessment of absolute Tc-99m tetrofosmin retention in the myocardium as an index of myocardial blood flow and coronary flow reserve by gated-SPECT/CT: a feasibility study.
Publication TypeJournal Article
Year of Publication2015
AuthorsApostolopoulos, D. J., Kaspiri A., Spyridonidis T., Patsouras N., Savvopoulos C. A., Davlouros P., Vassilakos P. J., & Alexopoulos D.
JournalAnn Nucl Med
Volume29
Issue7
Pagination588-602
Date Published2015 Aug
ISSN1864-6433
Abstract

OBJECTIVE: Estimation of myocardial blood flow (MBF) and coronary flow reserve (CFR) by SPECT myocardial perfusion imaging (MPI) remains challenging. Our aim was to approximate MBF and CFR by quantifying the absolute Tc-99m tetrofosmin retention in the myocardium via gated-SPECT/CT MPI.METHODS: Tracer retention was calculated on the basis of the microsphere kinetic model and served as an index of MBF at stress and rest (sMBFi, rMBFi). CFR was given by the sMBFi/rMBFi ratio. A planar first-pass acquisition during dipyridamole stress and at rest provided the data for tracer input determination. The input was represented by the integral of a gamma variate fitted on the time-activity curve of the left ventricle. Gated-SPECT/CT was performed 1 h post tracer injection and myocardial activity was measured in attenuation-corrected transaxial slices by a threshold VOI. The input was also compensated for tissue attenuation by measuring the distance from the centre of the left ventricle to the body surface on fused SPECT/CT slices. Input and uptake results were adjusted for planar-SPECT counting geometry differences by the aid of a phantom experiment. Thirty-nine subjects with low probability of coronary artery disease (CAD), age lower than 75 years and normal MPI (control group) were compared with 57 patients with documented CAD (CAD group).RESULTS: CFR and sMBFi values of CAD patients (1.39 ± 0.37 and 1.42 ± 0.35 ml/min/g) were considerably lower (p < 0.0001) than controls (1.68 ± 0.25 and 1.72 ± 0.37 ml/min/g). Significant difference in CFR (p = 0.03) was also noted between CAD patients with normal MPI (1.48 ± 0.38) and controls. However, sMBFi managed to discriminate certain CAD subgroups (normal MPI/ischemia/scar/scar and ischemia) more efficiently than CFR. Maximum heart rate-blood pressure product (RPP) during stress was an independent predictor of sMBFi and CFR. The other independent CFR correlates were resting RPP and diabetes mellitus, while sMBFi was associated with age, sex, smoking, and stress perfusion defects.CONCLUSIONS: Despite the low myocardial extraction fraction of Tc-99m tetrofosmin, an approximation of MBF and CFR is feasible with gated-SPECT/CT MPI. These flow indices together were able to discriminate CAD patients from controls and stratify different patient subgroups.

DOI10.1007/s12149-015-0982-6
Alternate JournalAnn Nucl Med
PubMed ID25971450

Επικοινωνία

Τμήμα Ιατρικής, Πανεπιστημιούπολη ΑΠΘ, T.K. 54124, Θεσσαλονίκη
 

Συνδεθείτε

Το τμήμα Ιατρικής στα κοινωνικά δίκτυα.
Ακολουθήστε μας ή συνδεθείτε μαζί μας.