Δημοσίευση

Women's expectations and intention to terminate pregnancy in case of abnormal findings at the second trimester level II ultrasound scan. A prospective, questionnaire-based, cross-sectional survey.

ΤίτλοςWomen's expectations and intention to terminate pregnancy in case of abnormal findings at the second trimester level II ultrasound scan. A prospective, questionnaire-based, cross-sectional survey.
Publication TypeJournal Article
Year of Publication2009
AuthorsAthanasiadis, A. P., Polychronou P., Mikos T., Pantazis K., Assimakopoulos E., Tzevelekis F., & Bontis J. N.
JournalFetal Diagn Ther
Volume25
Issue2
Pagination255-63
Date Published2009
ISSN1421-9964
Λέξεις κλειδιάAbortion, Eugenic, Adult, Cross-Sectional Studies, Female, Fetal Diseases, Humans, Intention, Pregnancy, Pregnancy Trimester, Second, Prospective Studies, Ultrasonography, Prenatal, Women
Abstract

OBJECTIVE: The aims of this study were: (1) to explore pregnant women's background knowledge and expectations of 2nd trimester ultrasound screening, and (2) to investigate women's intentions to proceed to pregnancy termination if fetal anomaly is detected at the 2nd trimester ultrasound screening.METHODS: A prospective, cross-sectional, questionnaire-based study. 300 consecutive pregnant women served as a convenience sample for this study. All the women had had a detailed, 2nd trimester, fetal anomaly scan. The questionnaire was a standardized but not validated, purpose-built structure consisting of five parts: (a) demographics, (b) anamnesis and obstetric history, (c) perceived aim of the scan, (d) expectations from the scan, and (e) intention to terminate pregnancy in case of fetal malformation diagnosis. Statistical analysis was performed with the SPSS 12.0 for Windows.RESULTS: The participants' mean age was 31.3 (21-45) years. 89.3% of the women filled in the questionnaire. The main reasons for the scan, according to the women, were to exclude fetal abnormalities and to assess the fetal karyotype. The main maternal expectations from the scan were to reduce maternal anxiety and to identify fetal malformations. 75.3% of the women were willing to terminate their pregnancy if fetal abnormalities were detected. Older women more commonly opted for pregnancy termination.CONCLUSION: The majority of participants have a correct notion about the aim of the ultrasound scan, their expectation is mainly anxiety reduction and a high percentage would proceed to pregnancy termination in the event of the detection of a fetal abnormality.

DOI10.1159/000223682
Alternate JournalFetal. Diagn. Ther.
PubMed ID19521092

Επικοινωνία

Τμήμα Ιατρικής, Πανεπιστημιούπολη ΑΠΘ, T.K. 54124, Θεσσαλονίκη
 

Συνδεθείτε

Το τμήμα Ιατρικής στα κοινωνικά δίκτυα.
Ακολουθήστε μας ή συνδεθείτε μαζί μας.