Δημοσίευση

Elimination of motion, pulsatile flow and cross-talk artifacts using blade sequences in lumbar spine MR imaging.

ΤίτλοςElimination of motion, pulsatile flow and cross-talk artifacts using blade sequences in lumbar spine MR imaging.
Publication TypeJournal Article
Year of Publication2013
AuthorsLavdas, E., Mavroidis P., Kostopoulos S., Glotsos D., Roka V., Koutsiaris A. G., Batsikas G., Sakkas G. K., Tsagkalis A., Notaras I., Stathakis S., Papanikolaou N., & Vassiou K.
JournalMagn Reson Imaging
Volume31
Issue6
Pagination882-90
Date Published2013 Jul
ISSN1873-5894
Λέξεις κλειδιάAdolescent, Adult, Aged, Aged, 80 and over, Algorithms, Artifacts, Female, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Lumbar Vertebrae, Magnetic Resonance Imaging, Male, Middle Aged, Movement, Pulsatile Flow, Reproducibility of Results, Sensitivity and Specificity, Signal-To-Noise Ratio, Spinal Diseases, Young Adult
Abstract

The purpose of this study is to evaluate the ability of T2 turbo spin echo (TSE) axial and sagittal BLADE sequences in reducing or even eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MRI examinations. Forty four patients, who had routinely undergone a lumbar spine examination, participated in the study. The following pairs of sequences with and without BLADE were compared: a) T2 TSE Sagittal (SAG) in thirty two cases, and b) T2 TSE Axial (AX) also in thirty two cases. Both quantitative and qualitative analyses were performed based on measurements in different normal anatomical structures and examination of seven characteristics, respectively. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion, pulsatile flow and cross-talk artifacts was evaluated. Based on the results of the qualitative analysis for the different sequences and anatomical structures, the BLADE sequences were found to be significantly superior to the conventional ones in all the cases. The BLADE sequences eliminated the motion artifacts in all the cases. In our results, it was found that in the examined sequences (sagittal and axial) the differences between the BLADE and conventional sequences regarding the elimination of motion, pulsatile flow and cross-talk artifacts were statistically significant. In all the comparisons, the T2 TSE BLADE sequences were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable of potentially eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MR images and producing high quality images in collaborative and non-collaborative patients.

DOI10.1016/j.mri.2013.03.006
Alternate JournalMagn Reson Imaging
PubMed ID23602722

Επικοινωνία

Τμήμα Ιατρικής, Πανεπιστημιούπολη ΑΠΘ, T.K. 54124, Θεσσαλονίκη
 

Συνδεθείτε

Το τμήμα Ιατρικής στα κοινωνικά δίκτυα.
Ακολουθήστε μας ή συνδεθείτε μαζί μας.