Δημοσίευση

Haemostatic profile of full-term, healthy, small for gestational age neonates.

ΤίτλοςHaemostatic profile of full-term, healthy, small for gestational age neonates.
Publication TypeJournal Article
Year of Publication2009
AuthorsMitsiakos, G., Papaioannou G., Papadakis E., Chatziioannidis E., Giougi E., Karagianni P., Evdoridou J., Malindretos P., Athanasiou M., Athanassiadou F., & Nikolaidis N.
JournalThromb Res
Volume124
Issue3
Pagination288-91
Date Published2009 Jul
ISSN1879-2472
Λέξεις κλειδιάBlood Coagulation Factors, Female, Greece, Hemostasis, Humans, Infant, Newborn, Infant, Small for Gestational Age, Male
Abstract

BACKGROUND: Small for Gestational Age (SGA) neonates often appear with haemostatic alterations, principally due to hepatic dysfunction that results from chronic intrauterine hypoxia. Polycythaemia and thrombocytopenia are common findings in this neonatal population.STUDY DESIGN: We performed a comparison of coagulation, natural inhibitors and fibrinolysis between SGA and Appropriate for Gestational Age (AGA) infants born full term [gestational age (G.A.) >37 weeks]. Study population consisted of 188 healthy newborns, 90 of whom were SGA (62 females and 28 males), while the rest were the control group (44 females and 54 males). Blood samples were obtained within 30 minutes following birth and before the administration of vitamin K. Investigation included: PT, INR, APTT, fibrinogen, coagulation factors II, V, VII, VIII, IX, X, XI, XII, vWillebrand factor, protein C and free protein S, antithrombin (AT), APCR, tPA and PAI-1. The independent t-test was used to compare the differences between the values of haemostatic parameters.RESULTS: Statistical analysis revealed a significant prolongation in PT, INR, elevated levels of tPA (p<0.015, 0.01 and 0.002 respectively) and a decrease in the values of XII and free protein S (p<0.045 and 0.007 respectively) in SGA full term neonates. The two groups had similar demographic characteristics (except birth weight), without significant differences in the values of other haemostatic parameters.CONCLUSIONS: Despite of statistically significant differences in PT, INR, values of tPA, XII and free protein S, levels of haemostatic factors range within laboratory references for healthy full term newborns. These findings were not accompanied with clinical manifestations of altered haemostasis.

DOI10.1016/j.thromres.2008.08.008
Alternate JournalThromb Res
PubMed ID18929397

Επικοινωνία

Τμήμα Ιατρικής, Πανεπιστημιούπολη ΑΠΘ, T.K. 54124, Θεσσαλονίκη
 

Συνδεθείτε

Το τμήμα Ιατρικής στα κοινωνικά δίκτυα.
Ακολουθήστε μας ή συνδεθείτε μαζί μας.