ARCOCT: Automatic detection of lumen border in intravascular OCT images.

TitleARCOCT: Automatic detection of lumen border in intravascular OCT images.
Publication TypeJournal Article
Year of Publication2017
AuthorsCheimariotis, G-A., Chatzizisis Y. S., Koutkias V. G., Toutouzas K., Giannopoulos A., Riga M., Chouvarda I., Antoniadis A. P., Doulaverakis C., Tsamboulatidis I., Kompatsiaris I., Giannoglou G. D., & Maglaveras N.
JournalComput Methods Programs Biomed
Volume151
Pagination21-32
Date Published2017 Nov
ISSN1872-7565
KeywordsArteries, Artifacts, Automatic Data Processing, Humans, Image Interpretation, Computer-Assisted, Reproducibility of Results, Stents, Tomography, Optical Coherence
Abstract

BACKGROUND AND OBJECTIVE: Intravascular optical coherence tomography (OCT) is an invaluable tool for the detection of pathological features on the arterial wall and the investigation of post-stenting complications. Computational lumen border detection in OCT images is highly advantageous, since it may support rapid morphometric analysis. However, automatic detection is very challenging, since OCT images typically include various artifacts that impact image clarity, including features such as side branches and intraluminal blood presence. This paper presents ARCOCT, a segmentation method for fully-automatic detection of lumen border in OCT images.METHODS: ARCOCT relies on multiple, consecutive processing steps, accounting for image preparation, contour extraction and refinement. In particular, for contour extraction ARCOCT employs the transformation of OCT images based on physical characteristics such as reflectivity and absorption of the tissue and, for contour refinement, local regression using weighted linear least squares and a 2nd degree polynomial model is employed to achieve artifact and small-branch correction as well as smoothness of the artery mesh. Our major focus was to achieve accurate contour delineation in the various types of OCT images, i.e., even in challenging cases with branches and artifacts.RESULTS: ARCOCT has been assessed in a dataset of 1812 images (308 from stented and 1504 from native segments) obtained from 20 patients. ARCOCT was compared against ground-truth manual segmentation performed by experts on the basis of various geometric features (e.g. area, perimeter, radius, diameter, centroid, etc.) and closed contour matching indicators (the Dice index, the Hausdorff distance and the undirected average distance), using standard statistical analysis methods. The proposed method was proven very efficient and close to the ground-truth, exhibiting non statistically-significant differences for most of the examined metrics.CONCLUSIONS: ARCOCT allows accurate and fully-automated lumen border detection in OCT images.

DOI10.1016/j.cmpb.2017.08.007
Alternate JournalComput Methods Programs Biomed
PubMed ID28947003