The english version of the website is under development. Wherever text appears in Greek, it means it has not been translated yet.

Δημοσίευση

Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis.

TitleDiagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis.
Publication TypeJournal Article
Year of Publication2018
AuthorsKiaos, A., Tziatzios I., Hadjimiltiades S., Karvounis C., & Karamitsos T. D.
JournalInt J Cardiol
Volume252
Pagination229-233
Date Published2018 Feb 01
ISSN1874-1754
KeywordsCoronary Angiography, Coronary Artery Disease, Humans, Magnetic Resonance Angiography, Magnetic Resonance Imaging, Cine
Abstract

INTRODUCTION: The purpose of this study was to investigate the accuracy of qualitative stress perfusion cardiac magnetic resonance (CMR) to diagnose ischemia-causing lesions according to different definitions of significant coronary artery disease (CAD), and magnetic field strength.METHODS: We searched PubMed, Web of Science, and the Cochrane Library for studies evaluating diagnostic performance of qualitative stress perfusion CMR for diagnosis of CAD versus coronary angiography or fractional flow reserve (FFR) from inception to 10 September 2017. We used hierarchical models to synthesize the available data.RESULTS: Sixty-seven studies (7113 patients) met the inclusion criteria. The patient-based analysis of studies using FFR as the reference standard demonstrated a mean sensitivity of 0.90 (95% confidence interval [CI], 0.85-0.93) and a mean specificity of 0.85 (95% CI, 0.80-0.89). The patient-based analyses for detecting coronary stenosis ≥50% and coronary stenosis ≥70% at 1.5T and for detecting coronary stenosis ≥50% and coronary stenosis ≥70%, at 3T, demonstrated a mean sensitivity of 0.82 (95% CI, 0.79-0.84), 0.86 (95% CI, 0.83-0.89), 0.90 (95% CI, 0.82-0.95), and 0.91 (95% CI, 0.79-0.96), respectively; with a mean specificity of 0.75 (95% CI, 0.71-0.80), 0.77 (95% CI, 0.71-0.81), 0.79 (95% CI, 0.69-0.86), and 0.74 (95% CI, 0.59-0.85).CONCLUSION: Qualitative stress perfusion CMR has high accuracy for the diagnosis of CAD, irrespective of the reference standard and the magnet strength. Studies using FFR as the reference standard had higher diagnostic accuracy on a patient level compared to studies using coronary angiography, with a notable difference in specificity.

DOI10.1016/j.ijcard.2017.11.066
Alternate JournalInt J Cardiol
PubMed ID29196090

Contact

Secretariat of the School of Medicine
 

Connect

School of Medicine's presence in social networks
Follow Us or Connect with us.