The english version of the website is under development. Wherever text appears in Greek, it means it has not been translated yet.

Δημοσίευση

The transluminal attenuation gradient in coronary CT angiography for the detection of hemodynamically significant disease: can all arteries be treated equally?

TitleThe transluminal attenuation gradient in coronary CT angiography for the detection of hemodynamically significant disease: can all arteries be treated equally?
Publication TypeJournal Article
Year of Publication2018
AuthorsFujimoto, S., Giannopoulos A. A., Kumamaru K. K., Matsumori R., Tang A., Kato E., Kawaguchi Y., Takamura K., Miyauchi K., Daida H., Rybicki F. J., & Mitsouras D.
JournalBr J Radiol
Volume91
Issue1087
Pagination20180043
Date Published2018 Jul
ISSN1748-880X
KeywordsAged, Computed Tomography Angiography, Coronary Angiography, Coronary Disease, Female, Hemodynamics, Humans, Male, Middle Aged, Predictive Value of Tests, Reproducibility of Results, Retrospective Studies
Abstract

OBJECTIVE: Results of the use of the transluminal attenuation gradient (TAG) at coronary CT angiography (CCTA) to predict hemodynamically significant disease vary widely. This study tested whether diagnostic performance of TAG to predict fractional flow reserve (FFR) ≤ 0.8 is improved when applied separately to subsets of coronary arteries that carry similar physiological flow.METHODS: 28 patients with 64 × 0.5 mm CCTA and invasive FFR in ≥1 major coronary artery were retrospectively evaluated. Two readers assessed TAG in each artery. The receiver operating characteristic (ROC) area under the curve (AUC) was used to assess the diagnostic performance of TAG to detect hemodynamically significant disease following a clinical use rule [negative: FFR > 0.8 or ≤ 25% diameter stenosis (DS) at invasive catheter angiography; positive: FFR ≤ 0.8 or ≥ 90% DS at invasive catheter angiography]. ROC AUC was compared for all arteries pooled together, vs separately for arteries carrying similar physiological flow (Group 1: all left anterior descending plus right-dominant left circumflex; Group 2: right-dominant RCA plus left/co-dominant left circumflex).RESULTS: Of the 84 arteries, 30 had FFR measurements, 30 had ≤25% DS and 13 had ≥90% DS. 11 arteries with 26-89% DS and no FFR measurement were excluded. TAG interobserver reproducibility was excellent (Pearson r = 0.954, Bland-Altman bias: 0.224 Hounsfield unit cm). ROC AUC to detect hemodynamically significant disease was higher when considering arteries separately (Group 1 AUC = 0.841, p = 0.039; Group 2 AUC = 0.840, p = 0.188), than when pooling all arteries together (AUC = 0.661).CONCLUSION: Incorporating information on the physiology of coronary flow via the particular vessel interrogated and coronary dominance may improve the accuracy of TAG, a simple measurement that can be quickly performed at the time of CCTA interpretation to detect hemodynamically significant stenosis in individual coronary arteries. Advances in knowledge: The interpretation of TAG may benefit by incorporating information regarding which coronary artery is being interrogated.

DOI10.1259/bjr.20180043
Alternate JournalBr J Radiol
PubMed ID29589976

Contact

Secretariat of the School of Medicine
 

Connect

School of Medicine's presence in social networks
Follow Us or Connect with us.