Comparison of two volumetric techniques for estimating liver volume using magnetic resonance imaging.

TitleComparison of two volumetric techniques for estimating liver volume using magnetic resonance imaging.
Publication TypeJournal Article
Year of Publication2002
AuthorsMazonakis, M., Damilakis J., Maris T., Prassopoulos P., & Gourtsoyiannis N.
JournalJ Magn Reson Imaging
Volume15
Issue5
Pagination557-63
Date Published2002 May
ISSN1053-1807
KeywordsAdult, Aged, Female, Humans, Linear Models, Liver, Liver Diseases, Magnetic Resonance Imaging, Male, Middle Aged, Reproducibility of Results
Abstract

PURPOSE: To compare the conventional technique of manual planimetry with the point counting technique for estimating liver volume from magnetic resonance imaging (MRI) data.
MATERIALS AND METHODS: This study comprised abdominal MR examinations of 38 consecutive patients. Evaluation of the images showed that liver size appeared normal in 27 patients and increased in 11. Liver volume was estimated using the techniques of planimetry and point counting. Both techniques were used in combination with the Cavalieri method of modern design stereology. A systematic slice sampling procedure was performed to estimate liver volumes using both volumetric techniques. The point counting technique was optimized by altering the point spacing of the grid. The agreement between the two techniques was found. Measurement repeatability of both volumetric techniques was also evaluated.
RESULTS: Both techniques allowed the same degree of optimization through the procedure of systematic section sampling. The application of a point spacing of 2.5 cm reduced the time measurement by a factor of 3.5 in relation with the time needed with planimetry. An excellent agreement was observed between the two volumetric techniques with mean differences (+/-SD) of 2.4 +/- 41.6 cm(3) and 8.5 +/- 49.8 cm(3) for the patients presenting normal and increased liver sizes, respectively. Both techniques were highly reproducible.
CONCLUSION: The point counting technique could be considered a more efficient approach than planimetry for estimating liver volume from MRI, due to its speed and simplicity.

DOI10.1002/jmri.10109
Alternate JournalJ Magn Reson Imaging
PubMed ID11997897

Contact

Secretariat of the School of Medicine
 

Connect

School of Medicine's presence in social networks
Follow Us or Connect with us.