The english version of the website is under development. Wherever text appears in Greek, it means it has not been translated yet.

Δημοσίευση

Conceptus radiation dose and risk from chest screen-film radiography.

TitleConceptus radiation dose and risk from chest screen-film radiography.
Publication TypeJournal Article
Year of Publication2003
AuthorsDamilakis, J., Perisinakis K., Prassopoulos P., Dimovasili E., Varveris H., & Gourtsoyiannis N.
JournalEur Radiol
Volume13
Issue2
Pagination406-12
Date Published2003 Feb
ISSN0938-7994
KeywordsAbnormalities, Radiation-Induced, Anthropometry, Child, Female, Gestational Age, Humans, Infant, Newborn, Mathematical Computing, Neoplasms, Radiation-Induced, Phantoms, Imaging, Radiation Dosage, Radiation Monitoring, Radiography, Thoracic, Risk Assessment, Thermoluminescent Dosimetry, X-Ray Intensifying Screens
Abstract

The objectives of the present study were to (a) estimate the conceptus radiation dose and risks for pregnant women undergoing posteroanterior and anteroposterior (AP) chest radiographs, (b) study the conceptus dose as a function of chest thickness of the patient undergoing chest radiograph, and (c) investigate the possibility of a conceptus to receive a dose of more than 10 mGy, the level above which specific measurements of conceptus doses may be necessary. Thermoluminescent dosimeters were used for dose measurements in anthropomorphic phantoms simulating pregnancy at the three trimesters of gestation. The effect of chest thickness on conceptus dose and risk was studied by adding slabs of lucite on the anterior and posterior surface of the phantom chest. The conceptus risk for radiation-induced childhood fatal cancer and hereditary effects was calculated based on appropriate risk factors. The average AP chest dimension (d(a)) was estimated for 51 women of childbearing age from chest CT examinations. The value of d(a) was estimated to be 22.3 cm (17.4-27.2 cm). The calculated maximum conceptus dose was 107 x 10(-3) mGy for AP chest radiographs performed during the third trimester of pregnancy with maternal chest thickness of 27.2 cm. This calculation was based on dose data obtained from measurements in the phantoms and d(a) estimated from the patient group. The corresponding average excess of childhood cancer was 10.7 per million patients. The risk for hereditary effects was 1.1 per million births. Radiation dose for a conceptus increases exponentially as chest thickness increases. The conceptus dose at the third trimester is higher than that of the second and first trimesters. The results of the current study suggest that chest radiographs carried out in women at any time during gestation will result in a negligible increase in risk of radiation-induced harmful effects to the unborn child. After a properly performed maternal chest X-ray, there is no need for individual conceptus dose estimations.

DOI10.1007/s00330-002-1352-z
Alternate JournalEur Radiol
PubMed ID12599008

Contact

Secretariat of the School of Medicine
 

Connect

School of Medicine's presence in social networks
Follow Us or Connect with us.